. LENOVOLenovo Storage V3700 V2 SFF Control Enclosure * (Pouze pro Lenovo partnery)
obrazek


Lenovo Storage V3700 V2 SFF Control Enclosure * (Pouze pro Lenovo partnery)

82 157 Kč

67 898 Kč bez DPH

Dostupnost (eshop):
na dotaz obnovit dostupnost
Dostupnost (prodejna):
na dotaz
Kód zboží: ELLNST6535EC2 (6535EC2)
Běžná cena: 83 389 Kč (při objednání mimo eshop)

Popis produktu

*Cena platí pouze pro registrované Lenovo partnery (registraci lze provést http://www.lenovopartner.com)

Form factor:

  • Lenovo Storage V3700 V2 Control Enclosure: 2U rack mount
  • Lenovo Storage V3700 V2 XP Control Enclosure: 2U rack mount
  • Lenovo Storage V3700 V2 Expansion Enclosure: 2U rack mount

Controller configuration:
Dual controller (known as node canister) configuration.

RAID levels :RAID 0, 1, 5, 6, and 10; Distributed RAID 5 and 6.
Controller cache: 16 GB per system (8 GB per node canister). V3700 XP is upgradeable to 32 GB (16 GB per node canister). Cache mirroring between the node canisters. Flash-backed cache protection (includes battery).

Drive bays

Up to 240 SFF drive bays per storage system:

  • 24 SFF drive bays in the control enclosure
  • 24 SFF drive bays in the expansion enclosure; up to 9 expansion enclosures

Up to 120 LFF drive bays per storage system:

  • 12 LFF drive bays in the control enclosure
  • 12 LFF drive bays in the expansion enclosures; up to 9 expansion enclosures

Intermix of SFF and LFF enclosures is supported.

Drive technology
SAS and NL SAS HDDs and SAS SSDs. Intermix of HDDs and SSDs is supported.

Internal storage capacity:

  • Up to 40 TB with 4x 10 TB 3.5" NL SAS or NL SATA HDDs
  • Up to 30.7 TB with 8x 3.84 TB 2.5" SATA SSDs
  • Up to 16 TB with 8x 2 TB 2.5" NL SAS or NL SATA HDDs
  • Up to 14.4 TB with 8x 1.8 TB 2.5" SAS HDDs

Drive connectivity

Dual-ported 12 Gb SAS drive attachment infrastructure.

Controller unit with two node canisters (ports per one node canister):

  • 24x 12 Gb SAS internal drive ports (SFF enclosure)
  • 12x 12 Gb SAS internal drive ports (LFF enclosure)
  • 1x 12 Gb SAS x4 (Mini-SAS HD SFF-8644) expansion port for the attachment of the expansion enclosures

Expansion unit with two expansion canisters (ports per one expansion canister):

  • 24x 12 Gb SAS internal drive ports (SFF enclosure)
  • 12x 12 Gb SAS internal drive ports (LFF enclosure)
  • 2x 12 Gb SAS x4 (Mini-SAS HD SFF-8644) expansion ports for the daisy chained attachment of the expansion enclosures

Drives:

SFF drives:

  • 300 GB and 600 GB 15K rpm SAS HDDs
  • 900 GB, 1.2 TB, and 1.8 TB 10K rpm SAS HDDs
  • 2 TB 7.2K rpm NL SAS HDDs
  • 400 GB, 800 GB, 1.6 TB, and 3.2 TB SAS SSDs
  • 1.92 TB, 3.84 TB, 7.68 TB, and 15.36 TB read-optimized SAS SSDs

LFF drives:

  • 300 GB and 600 GB 15K rpm SAS HDDs
  • 900 GB, 1.2 TB, and 1.8 TB 10K rpm SAS HDDs
  • 4 TB, 6 TB, 8 TB, and 10 TB 7.2K rpm NL SAS HDDs

Storage capacity:
Up to 3.68 PB (240x 15.36 TB SAS SSDs)

Host connectivity:
Standard ports (per control enclosure with two node canisters):

  • 4x 1 Gb iSCSI host ports (UTP, RJ-45) (2 ports per node canister)
  • 4x 12 Gb SAS host ports (Mini-SAS HD, SFF-8644) (2 ports per node canister; V3700 V2 XP only)

Optional additional ports on host interface cards (per control enclosure with two node canisters):

  • 8x 12 Gb SAS host ports (Mini-SAS HD, SFF-8644) (4 ports per node canister)
  • 8x 1 Gb iSCSI host ports (UTP, RJ-45) (4 ports per node canister)
  • 8x 10 Gb iSCSI or FCoE SFP+ host ports (SW fiber, LC) (4 ports per node canister)
  • 8x 16 Gb FC SFP+ host ports (SW or LW fiber, LC) (4 ports per node canister)

Host operating systems:
Microsoft Windows Server 2012, 2012 R2, and 2016; Red Hat Enterprise Linux (RHEL) 6 and 7; SUSE Linux Enterprise Server (SLES) 11 and 12; VMware vSphere 5.1, 5.5, 6.0, and 6.5.
Standard software features:
Virtualization of internal storage, Thin Provisioning, One-way Data Migration, FlashCopy snapshots (up to 64 targets), and Embedded GUI.

Configuration maximums:

Per system:

  • Maximum number of storage pools: 1,024
  • Maximum number of logical volumes: 2,048
  • Maximum logical volume size: 256 TB
  • Maximum number of drives in a RAID array: 16
  • Maximum number of RAID arrays: 128
  • Maximum number of drives in a distributed RAID array: 128 (including up to 4 spares)
  • Maximum number of distributed RAID arrays: 10
  • Maximum hot spare drives: No limit
  • Maximum number of host ports: 2,048
  • Maximum number of hosts: 256
  • Maximum number of host ports per one host: 32
  • Maximum number of snapshots: 2,048 (requires an optional license)
  • Maximum number of remote mirroring relationships: 2,048 (requires an optional license)

Cooling: Redundant cooling with the fan modules that are built into power supplies.
Power supply:Two redundant hot-swap 800 W AC power supplies.

Hot-swap parts:Node canisters, expansion canisters, SFP/SFP+ transceivers, drives, power supplies with fans.
Management interfaces:2x 1 GbE ports (UTP, RJ-45) in a primary/redundant configuration.
Web-based GUI; SSH CLI; SMI-S; SNMP and email notifications.

Security features:Secure Socket Layer (SSL), Secure Shell (SSH), user level security, LDAP authentication

Warranty: Three-year customer-replaceable unit and onsite warranty with 9x5 next business day terms. Optional warranty service upgrades are available through Lenovo: 24x7 coverage, 2-hour or 4-hour response time, 6-hour or 24-hour committed repair, 1-year or 2-year warranty extensions, Hard Drive Retention.

Dimensions: Height: 87 mm (3.4 in.); width: 483 mm (19.0 in.); depth: 556 mm (21.9 in.)
Weight:

  • Control enclosure (fully configured): 26 kg (57.3 lb)
  • Expansion enclosure (fully configured): 26.7 kg (58.9 lb)

Logo LENOVO

Produkt Lenovo Storage V3700 V2 SFF Control Enclosure * (Pouze pro Lenovo partnery) se nachází v kategorii , výrobce LENOVO

Technické parametry


Výrobce: LENOVO
EAN:
P/N: 6535EC2
Záruka [m]: 36


eo.cz patička kontakt +420 606 622 826 patička email obchod@eo.cz patička facebook

Chci odebírat akční nabídky:

 